Profile Main Screen

2-111

CONFIDENTIAL – Covered by ADS Software License Agreement

1998 - 2012 ADS LLC. All Rights Reserved.

that are low in comparison with confirmation readings.
Profile defaults to 100.

Floor Enter the appropriate value to filter the low-level noise

in the sensor. ADS does not recommend changing this
number.
The zero (default) value allows the sensor to adjust
automatically with changing noise levels.

Max Carrier Select the factor to use in detecting or limiting

zero (0) readings that may occur based on the location
characteristics and flow conditions. Increasing this value may
help eliminate erratic readings that produce excessive zeros;
decreasing this value can help detect authentic zeros. For
example, ADS recommends selecting 800 for dry weather
overflows. Profile defaults to 8000.

Gain This read-only value represents the factor applied to

raw velocity to determine average velocity when taking
diagnostic readings and calculating quantity and typical days
in the monitor. This parameter is editable through the
Quantity Coefficient Generator.

Suppression Select this checkbox to maximize sensor

sensitivity. ADS strongly recommends applying this option.
It is selected by default.

Reverse Select this checkbox to enable the monitor to

properly log reverse flow when it occurs at the monitoring
point. ADS recommends leaving this option unselected only
when you anticipate that reverse flows will not occur at the
monitoring point. Profile defaults to unselected.

Hanning Select this checkbox for monitors containing a

velocity board with an EPROM of 6.20 or newer. This option
is selected by default.

Store Data Select this checkbox to ensure the monitor logs

the velocity data. This option is selected by default.