Profile Main Screen

2-49

CONFIDENTIAL – Covered by ADS Software License Agreement

1998 - 2012 ADS LLC. All Rights Reserved.

Port Enter the number of the port through which wireless
communication will occur. Please consult ADS before
changing this parameter.

Max Retries Enter the maximum number of times you
want the monitor to attempt to establish communication
with the IntelliServe system following an initial failed
attempt.

High Depth Alarm Set up the following parameters when

you want the FlowShark monitor to send an alarm message to
an IntelliServe system when high flow depths occur at the
monitor.

Enable Select this checkbox to enable the High Depth
Alarm
function using the conditions specified in the High
Depth Alarm
Threshold and Return to Normal fields.

Threshold Enter the flow depth above which you want
the monitor to contact the IntelliServe system to initiate a
high depth alarm. Typically, this value is set to a height
slightly below, equivalent to, or exceeding the pipe height
to ensure notification occurs when the pipe is full or
surcharge conditions exist.

Note: To prevent potential false alarms, input a value
greater than 1 into the Readings to Average field of the
Unidepth Averaging section.

Return to Normal Enter the flow depth below which
you want the monitor to send a message to the ADS
IntelliServe system indicating the high depth conditions
no longer exist at the location.

High High Depth Alarm Set up the following parameters

when you want the FlowShark monitor to send a High High
Depth Alarm
message to an ADS IntelliServe system when
exceedingly high flow depths occur at the monitor.

Enable Select this checkbox to enable the High High
Depth Alarm
function using the conditions specified in