Trigger Enter the pressure depth reading at or below
which you want the monitor to initiate a low depth alarm.

Return to Normal Enter the pressure depth reading at or
above which you want the monitor to terminate alarming
conditions corresponding to a low depth alarm and report
this change in alarm status.

Readings to Average Enter or use the arrows to designate

the number of consecutive readings you want the monitor to
average to produce a value against which to compare the
triggers for the depth alarms. This feature prevents false
alarms from occurring due to unstable or erratic flow
conditions. When the number entered into the Readings to
Average
field is greater than 1, the monitor creates and stores
the new entity, DMLI_AVG (DMLI2_AVG for monitoring
point 2), which is collected and stored in the Profile database.
Select the Store Data checkbox to store the averaged
Unidepth data values (DLMI_AVG or DMLI2_AVG) to the
Profile database.

Pump Device

Editing the pump device enables Profile to generate pump
quantities for 4500, 5500, or 5600 series flow monitors. The pump
device window allows you to specify the active pumps and
designate the input channel to which each pump is connected. Edit
the pump device in the following way: