Store Data Select this checkbox to ensure the monitor logs

the smart depth data to the monitor memory. This checkbox is
selected by default.

Advanced Select this button to access the Advanced

Parameters window.

Note: Modifications made to the Advanced Parameters
should be performed only by or under the guidance of
trained ADS personnel. Therefore, ADS recommends
leaving the default settings in place.

DAC Gain Choose the method for managing the
amplification of the analog signal that returns to the sensor.
Select the Auto (default) option to allow the monitor to
automatically optimize the amplification of the signal.
Select the Manual option to enter a fixed value between -
12dB (lower amplification) and +12dB (higher
amplification).

Surcharge Detection Select the Disable checkbox to
prevent the monitor from implementing the Surcharge
Detection function when processing smart depth data. For
locations that typically do not experience surcharges,
disabling Surcharge Detection eliminates the processing
time required for this function and, as a result, conserves
monitor power.

Physical Offset Enter the physical distance from the face of

the ultrasonic depth sensor to the crown (top) of the pipe.

Pipe Height This read-only field displays the pipe height at

the monitoring point at which the sensor is installed.

Channel Select the channel number of the port on top of the

monitor to which the sensor device is connected.

Sensor Select the source from which to measure the

temperature used when compensating for temperature in
Ultrasonic Depth Sensor readings. The channels correspond
to the sensors connected to those channels (ports) on the
monitor. The option selected here should be consistent with