Manually entering a confirmation – ADS Environmental Services Profile Software 950015B6 User Manual

Page 233

Advertising
background image

Quantity Coefficient Generator

4-11

CONFIDENTIAL – Covered by ADS Software License Agreement

1998 - 2012 ADS LLC. All Rights Reserved.

monitoring location which may affect the hydraulics of the
flow.

Manually Entering a Confirmation

Manually enter field confirmations on the confirmation table in the
Quantity Coefficient Generator in the following way. Widen or
narrow the columns on the table, as necessary, by positioning the
mouse cursor between the columns and dragging the field to the left
or right:

Insert
button

1. Select the Insert toolbar button to position the cursor at the first

field of a new row on the confirmation table.

2. Enter the field confirmation information: Date, Time,

Method, Depth, +/-, PeakVel, +/-, Quantity, +/-, Silt, Crew,
and Comments. Refer to the Confirmation Table Reference on
page 4-9 for more information on the individual columns of the
confirmation table.

Note: You must enter at least a Depth and PeakVel
measurement (velocity confirmation) or a Depth and
Quantity measurement (quantity confirmation) to generate
coefficients.

3. Review the default Friction Factor value from the database,

and if necessary, enter new values.

Note: It is recommended that the Friction Factor remain
at the system default until enough independent information
is gathered to justify a change.

Recalculate
button

4. Select the Recalculate toolbar button to regenerate the

confirmation statistics.

The Quantity Coefficient Generator calculates and displays the
confirmations.