28-31 days for the most beneficial results; Profile
requires at least 7 days of data.

Finally, select the Calculate button to determine a
historical baseline for the selected time span and
display a graphical representation of the data. Select
the Close button to exit the graph and return to the
Edit MLI Device Properties dialog.

Note: Select the View button in the Velocity Scrubbing
section at any time to display the historical data pattern for
the selected location.

Automatic Pressure Calibration Select the Enable
checkbox to ensure the monitor automatically calibrates
the pressure depth data to read consistently with the
ultrasonic depth data. The monitor will compare the
pressure depth data to the ultrasonic data throughout the
day. At midnight each day, the monitor will apply a new
offset based on the difference between the two sensors
using the 15 previous good ultrasonic depth readings.

Modem Setup

Note: This device applies only to monitors equipped with
roaming SIM cards for wireless communication and
requires advanced knowledge involving wireless networks.
Therefore, ADS strongly recommends contacting
Customer Support for guidance and assistance before
attempting to set up this device.