Select or enter the total, consecutive number of times you
want the monitor to pulse the sampler (fill a bottle) within
a single interval each time the trigger condition is satisfied
in the Samples Per Wakeup field. Profile defaults to 1.

Select or enter the amount of time the monitor pauses
between sending pulses to the sampler in the Delay field.
This feature applies only when you configure the monitor
to pulse the sampler more than one time at each interval.
Profile defaults to 2 seconds.

Data Optimization Use the following options to obtain the

most accurate velocity and pressure depth data:

Velocity Editing Select this checkbox to ensure the
monitor confirms questionable or erroneous velocity
readings based on the historical relationship between the
ultrasonic depth and velocity data for the location.

Automatic Pressure Calibration Select this checkbox
to ensure the monitor automatically calibrates the pressure
depth data to read consistently with the ultrasonic depth
data. The monitor will maintain a running average of the
difference between the pressure depth data and the
ultrasonic data throughout the day. At midnight each day,
the monitor will apply a new offset based on the most
recent difference in the running average.

Scrubbing Algorithm Select the scrubbing algorithm you

want the monitor to apply when evaluating ultrasonic depth,
Smart Depth, or pressure depth to determine Unidepth from
the following:

Average-Depth Bias Choose this option to ensure the
monitor excludes unusual spikes and drops that may exist
in the depth readings when calculating Unidepth. Spikes
and drops represent isolated, inconsistently high (spikes)
or low (drops) depth readings that fall outside a predefined
tolerance or range.

Low-Depth Bias Choose this option to ensure the
monitor excludes unusual spikes that may exist in the depth
readings when calculating Unidepth.