ADS Environmental Services Profile Software 950015B6 User Manual

Page 278

Advertising
background image

Diagnostics

6-7

CONFIDENTIAL – Covered by ADS Software License Agreement

1998 - 2012 ADS LLC. All Rights Reserved.

Deactivate This log is created anytime the Deactivate monitor

function is performed. Log details include the name of the
monitor location, date and time the deactivation occurred, and the
resulting success or failure of the deactivation process.

Depth Confirmation This log contains the information

gathered after confirming depth at a specific monitor location. It
includes the monitor location name, the field measurements taken,
the firings used in the confirmation, and the associated depth
sensor readings.

Firmware Download This log is created anytime a monitor

firmware upgrade is performed and includes the name of the
monitor location receiving the firmware download, date/time at
which the download occurred, the firmware update version, and
success or failure of the download process.

Monitor Status This log generates each time the Monitor

Status function is initiated in the Diagnostics function and
contains details of the current state of the monitor.

Power Saving This log records details each time the Power

Saving function is used and contains details on the days and times
the monitor modem battery power is on or off.

Pressure This log contains the specific information recorded

after taking a pressure depth reading during an activity such as a
confirmation or device diagnostic procedure. It includes the
monitor location name, the date on which the reading was taken,
the current pressure depth sensor configuration parameters, and
the depth and temperature readings recorded from the sensor.

PVD This log contains specific information concerning a selected

peak velocity and depth (PVD) confirmation event. It includes the
field measurements, monitor measurements, differences between
measurements, checklist results, and any comments entered during
the confirmation.

Rain This log provides the details concerning a reading taken

involving the rain device. It includes the name of the rain gauge
location, the date/time at which the reading occurred, the rain
device parameters, and reading obtained.

Advertising