+/- Enter the accuracy (plus/minus) for the measured depth.

This is the level of accuracy of the depth reading based on the
field crew's ability to obtain accurate measurements. For
example, a factor that could influence accuracy may be a
choppy flow surface.

PeakVel Enter the manually obtained peak velocity of the

flow.

+/- Enter the plus/minus accuracy of the peak velocity.

AvgVel This field displays the results of the PeakVel

multiplied by the Average-to-Peak ratio (from the Average-
to-Peak
table created in the Installation Generator or using
the .90 default ratio).

Quantity Use this column to enter the field-measured quantity

for a quantity confirmation.

+/- Enter the plus/minus accuracy of the quantity confirmation.

Calc/Q This field displays the calculated quantity based on

the confirmation information.

Silt Enter the silt depth, if any, at the monitoring point as

measured during the field confirmation. The default value is 0
inches. This field can be widened to accommodate larger
numbers, if necessary.

HC This field displays the calculated hydraulic coefficient

derived from the field confirmation.

Roughness This field displays the calculated roughness

derived from the field confirmation or a manually set
roughness.

Slope This field displays the calculated slope derived from

field confirmations or a manually set slope.

Crew Enter the name or identification of the field crew who

performed the confirmation.

Comments Enter any information relevant to the field

confirmation, such as unusual or unique conditions at the

Advertising