Gain This read-only value represents the factor applied to

the raw velocity readings to determine average velocity for
calculating quantity and typical days in the monitor. The
Gain is not applied to velocity readings reported in
Diagnostics where a raw velocity reading is reported to
facilitate comparison with manual measurements.

Cross Check Gain Enter the value by which to multiply

raw velocity readings in the monitor to determine average
velocity for calculating CROSS_VELOCITY events in the
monitor.

Store Data Select this checkbox to ensure the monitor logs

the velocity data to memory. This option is selected by
default.

Advanced Select this button to access the Advanced

Parameters window.

Note: Modifications made to the Advanced Parameters
should be performed only by or under the guidance of
trained ADS personnel. Therefore, ADS recommends
leaving the default settings in place.

DAC Gain Choose the method for managing the
amplification of the analog signal that returns to the sensor.
Select the Auto (default) option to allow the monitor to
automatically optimize the amplification of the signal.
Select the Manual option to enter a fixed value between -
12dB (lower amplification) and +12dB (higher
amplification).

Ping Amplitude Choose the method for managing the
amplification of the analog signal that is sent out, or
transmitted from, the sensor. Smaller pipes typically
require lower (quieter) amplitude values, while larger pipes
typically need stronger (louder) amplitudes. Select the
Auto (default) option to allow the monitor to automatically
optimize the amplification of the signal. Select the Manual
option to enter a percentage of full amplification at which

Advertising