ArcGlide THC Instruction Manual 806450

107

2 – Installation

All ArcGlide CNC inputs can be configured for dry contact closures or 12 V – 24 V sourced inputs.

Pin No.*

Color

Signal name

Dry contact or sourced circuit

13

Orange

IHS Complete output A

14

Black

IHS Complete output B

15

White

Retract Complete output A

16

Red

Retract Complete output B

17

Green

Machine Motion output A

18

Red

Machine Motion output B

19

Blue

THC Error output A

20

Red

THC Error output B

21

Yellow

Torch Breakaway output A

22

Red

Torch Breakaway output B

23

Brown

CNC Spare output A

24

Red

CNC Spare output B

25

Orange

Motion Interlock input +

**

26

Red

Motion Interlock input -

**

27

White

Interlock output A

28

Green

Interlock output B

29

Blue

Common

30

Green

Common

31

Yellow

Common

32

Green

Common

33

Brown

+24 VDC output

34

Green

+24 VDC output

35

Orange

+24 VDC output

36

Not connected

37

Not connected

*

Pin numbers are the same on both ends of the cable.

**

The circuit is closed if a jumper is used.

normally open

A

B

normally open

A

B

normally open

A

B

normally open

A

B

normally open

A

B

normally open

A

B

+24 V

A

B

+24 V

+24 V

+24 V

Advertising