Arcglide communication configuration examples – Hypertherm THC ArcGlide User Manual

Page 61

Advertising
background image

ArcGlide THC Instruction Manual 806450

61

2 – Installation

ArcGlide communication configuration examples

Table 5 lists the ArcGlide configurations on the following pages. If you are viewing this manual online, click the page
number in the left column to view that configuration.

Table 5

Drawing

number and

page

Connection to plasma

Connection to CNC

1

page 63

Hypernet to multiple HPR or HPRXD plasma
systems, each with plasma interface board
141162. Requires an Ethernet switch.

Hypernet to Hypernet-capable CNCs.

2

page 64

Discrete to HPR or HPRXD plasma system with
plasma interface board 141094.

Hypernet to Hypernet-capable CNCs.

3

page 65

Discrete to HPR or HPRXD plasma system with
plasma interface board 141094.

Discrete to a CNC with a Picopath interface.
Serial cable from CNC to plasma system, supplied
by the table manufacturer.

4

page 66

Discrete to HPR or HPRXD plasma system with
plasma interface board 141094.

Discrete to third party CNC. Serial cable from
CNC to plasma system, supplied by the table
manufacturer.

5

page 67

Discrete to HPR400XD or HPR800XD plasma
system with plasma interface board 141094.

Discrete to third party CNC. Serial cable from
CNC to plasma system, supplied by the table
manufacturer.

6

page 68

Discrete to HPR or HPRXD plasma system with plasma interface board141094, showing circuits,
signals, and connections to terminal blocks.

7

page 69

Discrete to HSD130 plasma system with the
plasma interface board 141094, machine interface
cable (123209) from the plasma interface board to
the control board in the plasma system.

Discrete to a CNC with a Picopath interface.

8

page 70

Discrete to MAX 200, HT2000 or HT2000 LHF
plasma system with plasma interface board
141094. 1 X 6 interface cable between the
plasma interface board and plasma system.

Discrete to a CNC with a Picopath interface.

9

page 71

Discrete to MAX 200, HT2000 or HT2000 LHF plasma system with plasma interface board 141094,
showing circuits, signals, and connections to terminal blocks.

10

page 72

Discrete to Powermax plasma systems with
plasma interface board 141094 and Powermax
interface cable 023206 between the plasma
interface board and the Powermax plasma system.

Discrete to a CNC with a Picopath interface.

Advertising