ArcGlide THC Instruction Manual 806450

A – ArcGlide THC Serial Communication Protocol

IHS Speed

Command ID

Data

Examples

IS

10 – 150 in/min

254 – 3,810 mm/min

>IS6002< IHS Speed set to 60 in/min.

>IS152468< IHS Speed set to 1,524 mm/min.

>IS?DB< Inch or metric query from the CNC.

Sets the slow speed for the final approach to the workpiece during an IHS operation and the slow speed for
manual moves.

Default: 1,524 mm/min or 60 in/min

Use the default when using the Hypertherm lifter with the ArcGlide.

Speed Gain

Command ID

Data

Examples

SG

1 – 10 (1 = lowest gain)

>SG5CF< Speed Gain set to 5.

>SG?D9< Query from the CNC.

This gain value regulates the speed gain of the lifter.

Default: 5

Use the default when using the Hypertherm lifter with the ArcGlide.

Position Gain

Command ID

Data

Examples

PG

1 – 10 (1 = lowest gain)

>PG5CC< >PG05FC< Either command sets
Position Gain to 5.

>PG?D6< Query from the CNC.

This gain is used for closed loop positioning.

Default: 5

Use the default when using the Hypertherm lifter with the ArcGlide.