Error 21 – Ohmic tip sense

Nozzle Contact Sense input does not turn ON during initial height sense. The ArcGlide uses stall force to sense the
workpiece.

Is the nozzle touching the workpiece?

Yes

No

Examine the workpiece

for an oil or plastic

coating, or too much

rust or dirt.

Yes

Is something on the

workpiece

preventing nozzle

contact sense?

Is the Stall Force set

too low?

Yes

Verify that the settings

that affect the motor
and lifter are correct

(gains for speed and

position, encoder

counts, slide length,

current limit, and stall

force).

Perform an IHS test. If

the torch is not reaching

the workpiece. Increase

the Stall Force setting

by 1. Repeat the IHS

test after each setting

change. If the problem

continues, contact

Hypertherm Technical

Service.

No

No

Examine the cutting

machine slats for

damage or slag

build-up.

No

Does the workpiece

have an electrical
connection to the
cutting machine?

Is a mechanical bind

preventing the torch

from reaching the

workpiece?

Yes

Monitor the lifter for

smooth motion.

Examine the lifter

motion for obstructions.

Continued on