Hypertherm THC ArcGlide User Manual

Page 225

Advertising
background image

ArcGlide THC Instruction Manual 806450

225

4 – Maintenance

J1 Plasma interface

Pin No.

Signal

Pin No.

Signal

1

HPR Rx -

2

HPR Tx -

3

RS-422 communication

4

Ground

5

Ground

6

Ground

7

Ground

8

Not connected

9

Not connected

10

Not connected

11

Not connected

12

Corner A

13

Pierce A

14

Hold A

15

Plasma start relay A

16

Rem on A

17

Not connected

18

Ground

19

Optional 24 V from HPR

20

HPR Rx +

21

HPR Tx +

22

HPR turned ON

23

Motion

24

Error

25

Ramp-down error

26

HPR NR

27

Not connected

28

Not connected

29

Not connected

30

Not connected

31

Corner B

32

Pierce B

33

Hold B

34

Plasma start relay B

35

Rem on B

36

Ground

37

Optional 24 V from HPR

38

Ground

J2 (+24 V or contact closure inputs to the THC from a generic plasma system)

Pin No.

Signal

Pin No.

Signal

1

Motion

2

Common

3

Error

4

Common

5

Ramp error

6

Common

7

Not ready

8

Common

9

Spare input

10

Common

11

Common

12

Common

13

Common

14

Common

15

Plasma system 24 VAC line*

16

Plasma system 24 VAC neutral**

* Pin 15 can be changed to +24 VDC.

** Pin 16 can be changed to -24 VDC.

Advertising