ArcGlide THC Instruction Manual 806450

201

4 – Maintenance

19

EXCESS PLATE CONTACT

The Nozzle Contact input, while cutting, was turning ON and OFF numerous times in succession or was ON
continuously for a period of time. This error can occur whether or not the nozzle is contacting the workpiece.
For a flow chart, see

Error 19 – Excess plate contact on page 186.

The nozzle is contacting
the workpiece

• Arc Voltage Control is off.

• Enable Arc Voltage Control.

• The Arc Voltage setpoint is set

too low.

• Verify that the Arc Voltage setpoint

matches the value in the plasma cut
chart.

• Sample Voltage is ON and the

IHS is inaccurate.

• If Sample Voltage is ON, verify that the

torch height is correct by performing an
IHS test.

• The travel speed is too slow.

• Verify that the cut speed equals the cut

speed in the cut chart. If the value is red,
the speed control on the operator
console is overriding the travel speed.

• The Torch Height Disable is not

turning ON when approaching
or exiting corners, holes, cutting
a small radius, or when crossing
a kerf. Torch Height Disable
should be OFF when the
cutting machine is moving at
program speed. Torch Height
Disable should turn ON when
cutting corners, a small radius,
or other situations when the cut
speed is slower than program
speed.

Torch Height Disable

should be ON

when piercing.

• In a discrete connection to the ArcGlide

control module, check the output wiring
at the CNC and the input wiring at the
ArcGlide.

• Verify the Torch Height Disable settings

in the Speeds screen of the Phoenix
software are set correctly. Torch Height
Disable speed defines the percentage of
the Cut Speed at which to disable the
torch height control.

• The workpiece is not lying flat

on the table or is warping due to
heat from the arc.

• Verify that the workpiece is lying flat and

not warping while cutting. If so, set
Nozzle Contact Cutting to OFF in the
Plasma Process screen.

• Error occurs only when marking. • If the problem occurs while marking,

verify that these parameters are set
according to the marker cut chart:

Marking Speed

Marking Height

Set Arc Voltage

The nozzle is not
contacting the workpiece.

• There is slag build-up between

the shield and the nozzle.

• Examine the consumables for damage or

slag build-up between the shield and
nozzle.

• The ohmic contact wire shorted

to ground after the cut started.

• Examine the ohmic contact wire for

damage to the insulation around the
wire.

• The torch is operating in a water

table and the water is above the
surface of the workpiece.

• If you are cutting in a water table, set

Nozzle Contact Cutting to OFF in the
Plasma Process screen.

Error

Description

Causes

Solutions