Hypertherm THC ArcGlide User Manual

Page 152

Advertising
background image

152

ArcGlide THC Instruction Manual 806450

3 – Operation

MANUAL DOWN – The lifter initially jogs down 0.254 mm (0.01 inch). After 0.5 second, it begins
continuous downward motion at the IHS Speed. After 2 seconds, the lifter increases the speed to the
programmed Slow Speed. The lifter does not change the output signals; if the torch is already cutting, it
continues to cut.

END CUT RETRACT – The lifter moves the torch up at Full Speed to the Retract Height. When the torch is
in position at the Retract Height, the lifter activates the Retract Complete output signal to the CNC and
enters the Idle state.

Hypernet Status: ON, OFF, or PM (protocol mismatch). See Error 41 in Critical Errors on page 149 for more

information.

Switch Diagnostics: Allows the operator to test the status of the switches on the front panel of the HMI. ON or OFF

displays as each switch is pushed or moved.

<back> Select this line to return to the Main screen.