Connect the ohmic wire to other plasma systems, Ground the lifter – Hypertherm THC ArcGlide User Manual

Page 80

Advertising
background image

80

ArcGlide THC Instruction Manual 806450

2 – Installation

Connect the ohmic wire to other plasma systems

Do not splice ohmic wires.

If your plasma system is not an HPRXD system, connect the ArcGlide ohmic
wire to the torch:

1. Unfasten the cable tie around the coiled ohmic wire and straighten the

ohmic wire.

2. Install the free end of the ohmic wire on the IHS tab on the torch retaining

cap.

Ground the lifter

The lifter must be grounded correctly to make sure the lifter performs
accurate initial height sense (IHS).

To ground the lifter:

1. Remove the bottom nut and washer of the grounding assembly on

the lifter.

2. Fit the terminal on the ground wire over the grounding post.

3. Replace the bottom nut and washer on the ground post and

finger-tighten it so the terminal is in contact with the washer and
bottom nut.

4. Connect the other end of the ground wire to a terminal on the table

ground bus bar on the cutting machine.

5. Verify that the wire is not in the path of the lifter mechanics

See

Recommended grounding and shielding practices on page 55 for

more information.

2

Ohmic wire

Advertising