Hypertherm THC ArcGlide User Manual

Page 149

Advertising
background image

ArcGlide THC Instruction Manual 806450

149

3 – Operation

ERR 6 LOWER LIM DURING OPR – The lifter reached the lower limit during operation.

ERR 7 FAILED MOVE TO IHS START – The lifter failed to reach IHS Start Height.

ERR 8 FAILED TO CONTACT PLATE – The torch failed to contact the workpiece within 60 seconds.

ERR 9 FAILED TO CLEAR PLATE – The torch failed to retract and break ohmic contact within 10 seconds.

ERR 10 FAILED TO MOVE TO XFER HT – The torch failed to retract to Transfer Height within 10 seconds.

ERR 11 IHS SYNC TIMEOUT – The torch reached the IHS position but IHS SYNC was not released within
60 seconds.

ERR 12 TRANSFER TIMEOUT – The Transfer signal was not received from the plasma system within
60 seconds.

ERR 13 LOST TRANSFER – The plasma arc was lost during the cut.

ERR 14 FAILED MOVE TO PIERCE – The lifter failed to reach Pierce Start Height within 10 seconds.

ERR 15 FAILED MOVE CUTHEIGHT – The lifter failed to reach Cut Height during Accel Delay.

ERR 16 RAMPDOWN TIMEOUT – The Motion signal was not removed within 10 seconds.

ERR 17 RETRACT TIMEOUT – The lifter failed to retract within 20 seconds at the end of the cut.

ERR 18 ERR SAMPLED ARC VOLTS – During the sample arc voltage operation, there was an excessive
change in sample voltage.

ERR 19 EXCESS PLATE CONTACT – During the cut, the torch made excessive contact with the
workpiece.

ERR 20 PLASMA SUPPLY – Plasma system error.

ERR 21 OHMIC TIP SENSE – Nozzle Contact Sense was enabled but not sensed.

Critical Errors

ERR 23 INPUT VOLTAGE LOW – The incoming AC line voltage is more than 20% low.

ERR 24 INPUT VOLTAGE HIGH – The incoming AC line voltage is more than 15% high.

ERR 25 OVER-TEMPERATURE – The temperature of the processor has exceeded the maximum value.

ERR 26 MOTOR DRIVE – The temperature for the motor drive has exceeded the maximum value.

ERR 27 INTERLOCK TRIPPED – The safety interlock was removed.

ERR 28 BREAKAWAY TRIPPED – The torch breakaway was removed.

ERR 29 FIELD SUPPLY FAILED – The +5 V, +12 V, or -12 V supply has failed.

ERR 30 STALL CALIBRATION – Stall Calibration down motion failed after power was turned ON.

Advertising