ArcGlide THC Instruction Manual 806450

79

2 – Installation

Connect the ohmic wire from HPRXD plasma systems

Do not splice ohmic wires.

Figure 14

To connect the ohmic wire from an HPRXD torch to the ArcGlide lifter:

1. Remove the top cover of the motor compartment on the lifter.

2. Disconnect the existing ohmic wire from the J5 connector on the underside of the lifter interface board.

3. Remove the ohmic wire from the motor compartment of the lifter.

4. Cut the terminal end off the ohmic wire from the HPRXD torch and strip 5 mm (0.2 inch) of the covering.

5. Insert the end of the ohmic wire from the HPRXD system through the grommet in the bottom of the motor

compartment of the lifter.

6. Insert the stripped HPRXD ohmic wire into the J5 connector on the underside of the lifter interface board.

7. Use cable ties to fasten the wire to the mounts on the inside back wall of the lifter compartment.

8. Replace the top cover of the motor compartment.

6

7

5

Front view of the motor

enclosure

Lifter motor

Ohmic wire from an HPRXD

plasma system

Side view of the lifter

Advertising