Install the optional pneumatic breakaway – Hypertherm THC ArcGlide User Manual

Page 82

Advertising
background image

82

ArcGlide THC Instruction Manual 806450

2 – Installation

Install the optional pneumatic breakaway

Installing the torch breakaway kit on the lifter assembly also requires using parts of the torch mounting block kit of the
proper diameter.

The maximum inlet pressure of the pressure regulator is 10.2 bar (150 psi). Typically, the maximum inlet pressure
should be set at 6.9 bar (100 psi).

The routing of the leads, stall force, IHS speed, and acceleration or deceleration movements can affect the pressure
setting required to achieve reliable operation.

If air pressure is removed, the breakaway must be manually repositioned when air is applied. The breakaway will not
rest in its position when air pressure is lost.

Figure 16

To install the pneumatic breakaway:

1. Mount the fiberglass bracket to the lifter using the 4 hexagonal screws.

2. Mount the breakaway to the fiberglass bracket using the 6 screws.

3. Attach the torch mounting block to the breakaway with the collar and 2 screws.

4. Wire the electrical output of the breakaway to the torch collision input of the CNC.

5. Mount the filter/regulator.

6. Connect the tubing between the filter/regulator and the breakaway.

Breakaway pressure switch,

normally-open

Breakaway

Moisture drain

Pressure gauge

Black = 1

Filter/regulator

Inlet port 0.25 inch NPTF*

6.9 bar (100 psi)

Wire to emergency stop

circuit

33.34 mm
(1.31 inch)

Tubing

Pin 1

Pin 4

Pin 3

Blue = 3 (not connected)

Brown = 4

* National pipe thread female

2 hexagonal screws, 4 mm X

40 mm (8-32 X 1.50 inch),

supplied by the customer