ArcGlide THC Instruction Manual 806450

211

4 – Maintenance

ArcGlide PCBs

HMI processor board (228581)

In a Hypernet configuration, the Unit address switch (SW6) on the HMI processor board
must have the same address as the Unit address switch on the THC processor and the
Hypernet plasma interface boards. The default setting is 1.

Test points

Test point No.

Signal

TP10

+2.5 VDC

TP33

+3.3 VDC

TP37

+5 VDC

TP38

Ground

J4 LCD character module

Pin No.

Signal

Pin No.

Signal

1

DB6

2

DB7

3

DB4

4

DB5

5

DB2

6

DB3

7

DB0

8

DB1

9

WR\

10

E1 (lines 1 and 2)

11

Vee

12

RS

13

VOC

14

Vss

15

Not connected

16

E2 (lines 3 and 4)

Default settings = 1

TP10

J4 LCD character module

J3 Display ribbon cable

SW6 Unit address switch,
default setting = 1

J7 RJ45

J11 Rotary encoder input

J8 Operator console

LEDs

J10 IHS test
pushbutton

J9 Display

J12 Power input

TP 37

TP 38

TP 33

1

1

1

1

1

1

1

1

1