background image

ArcGlide THC Instruction Manual 806450

229

4 – Maintenance

LEDs

LED No.

Color

Signal

1

Red

Plasma system error

2

Slow blinking red

HPR Hypernet is ready

3

Rapid blinking red

Serial transmission

J3 Discrete interface

Pin No.

Signal

Pin No.

Signal

1

Start +

2

Start -

3

Hold +

4

Hold -

5

Pierce +

6

Pierce -

7

Corner +

8

Corner -

9

Not ready C

10

Not ready E

11

Ramp down error C

12

Ramp down error E

13

HPR error C

14

HPR error E

15

Transfer (Motion) C

16

Transfer (Motion) C

J4 Arc voltage*

Pin No.

Signal

1

Work +

2

Electrode -

* The arc voltage terminals on connector J4 must be connected to the I/O board in the plasma system.

J5 CNC interface

Pin No.

Signal

Pin No.

Signal

1

HPR Rx -

2

HPR Tx -

3

RS-422 Common

4

Motion

5

Error

6

Rampdown error

7

HPR not ready

8

Not connected

9

Not connected

10

Not connected

11

Not connected

12

Spare

13

Pierce A

14

Hold A

15

Start A

16

Not connected

17

Not connected

18

Ground

19

Not connected

20

HPR Rx +

21

HPR Tx +

22

Not connected

23

Motion

24

Error

25

Rampdown error

26

HPR not ready

Advertising