Hypertherm THC ArcGlide User Manual

Page 263

Advertising
background image

ArcGlide THC Instruction Manual 806450

263

A – ArcGlide THC Serial Communication Protocol

Voltage Gain

Command ID

Data

Examples

VG

1 – 10 (1 = lowest gain)

>VG5D2< Voltage Gain set to 5.

>VG?DC< Query from the CNC.

This gain is used for closed-loop arc voltage control.

Default: 5

Use the default when using the Hypertherm lifter with the ArcGlide.

Voltage Calibration

Command ID

Data

Example

VC

900 – 1,100 (0.900 – 1.100)

>VC10005A< Sets arc voltage calibration to a
value of 1.

This value calibrates the arc voltage measurement accuracy. It is the software equivalent of adjusting the
voltage divider board to correct for small unit-to-unit tolerances. The measured arc voltage is multiplied by this
correction value before it is displayed or used for voltage control.

Default: 1.000

Language

Command ID

Data

Example

LG

0 – 6

0 = English, 1 = German,
2 = Spanish, 3 = Italian,
4 = French, 5 = Portuguese,
6 = Dutch

>LG0C3< Sets language to English.

>LG?D2< Query from the CNC.

Sets the language displayed on the ArcGlide HMI. The ArcGlide control module always displays messages in
English.

Default: 0 (English)