Hypertherm THC ArcGlide User Manual

Page 175

Advertising
background image

ArcGlide THC Instruction Manual 806450

175

4 – Maintenance

Service active Hypernet links.

Data is automatically copied into the operating
parameters and the status is automatically transmitted.

I/O is updated and control
loops execute at 10 ms
intervals. Excess time in this
loop is spent servicing the
RS-422 connection.

10 ms interval?

No

Service RS-422 and check Tip Touch or

Tip Sense (on Screen 6 of the

control module).

Yes

Service watchdog timer.

Service analog I/O.

Read arc voltage.

Write motor current.

Read expansion inputs.

Check for critical errors.

Critical errors must be corrected before the power is
turned ON again. See

Table 8 – Critical Errors on

page 204 for more information.

Operating states

CNC Hypernet link active?

No

Use HMI operating parameters.

Use CNC discrete wire operating signals.

Yes

Use CNC operating

parameters.

Use Hypernet CNC

operating signals.

Station disabled.

Critical error?

Yes

Plasma remote power OFF.

No

Plasma remote power ON.

Plasma system Hypernet

link active?

No

Use discrete wire plasma system operating

signals and arc voltage.

Yes

Use Hypernet plasma system

operating signals and

arc voltage.