background image

ArcGlide THC Instruction Manual 806450

209

4 – Maintenance

Printed circuit board (PCB) block diagram for a Hypernet configuration

Figure 46

CNC with Hypernet

Control module

Lifter

HMI (optional)

HPR plasma system with Hypernet

Lifter interface board

Lifter interface

Motor brake encoder interface

Upper/lower limit switches

Tip touch

Station enable switch

Manual up/down switch

Breakaway switch

Laser pointer

Station active lamp

THC interface board

Lifter interface

Operator console interface

Plasma interface

Board interconnect

THC processor board

Board interconnect

LCD character module

Front panel LEDs

Hypernet interface

Plasma interface board

Hypernet interface

Arc voltage

Contact closure outputs from THC

Contact closure inputs to THC

Plasma interface

HMI processor board

Hypernet interface

LCD character module

Front panel LEDs

7-segment display interface

HMI 7-segment display board

Hypernet interface

Industrial Ethernet

switch

Key:

Hypernet connection

– – – – – –

Discrete connection

——————