4 – Maintenance

J3 Board interconnects

Pin No.

Signal

Pin No.

Signal

1

CNC Cycle Start input

2

CNC IHS Complete output

3

CNC IHS Disable input

4

CNC Retract Complete output

5

CNC AVC Disable input

6

CNC Machine Motion output

7

CNC IHS Sync input

8

CNC Error output

9

+5 VDC

10

Ground

11

CNC spare 1 input

12

CNC Breakaway output

13

CNC spare 2 input

14

CNC spare output

15

Interlock

16

CNC Dry Inputs 24 V

17

Not connected

18

Not connected

19

+5 VDC

20

Ground

21

Plasma Motion input

22

Plasma Corner output

23

Plasma Error input

24

Plasma Pierce output

25

Plasma Ramp Error input

26

Plasma Hold output

27

Plasma Not Ready input

28

Plasma Start output

29

+5 VDC

30

Ground

31

Plasma spare input

32

Plasma spare output

33

Plasma RS-422 RX

34

Plasma RS-422 Tx

35

Not connected

36

Plasma Dry Inputs 24 V

37

Lifter Station Enable

38

Plasma Remote On output

39

+5 VDC

40

Ground

41

Lifter Lower Limit input

42

Lifter Brake output

43

Lifter Upper Limit input

44

Not connected

45

Lifter Breakaway input

46

Not connected

47

Lifter Manual Up input

48

Not connected

49

+5 VDC

50

Ground

51

Lifter Manual Down input

52

Operator console enabled output

53

Lifter Change Consumable

54

Operator console error output

55

Encoder A

56

Operator console spare output

57

Encoder B

58

Not connected

59

+5 VDC

60

Ground

61

Operator console Disable input

62

1/50 Arc V -

63

Operator console Select input

64

1/50 Arc V +

65

Operator console Torch Up input

66

Ohmic contact sense -

67

Operator console Torch Down input

68

Ohmic contact sense common

69

+5 VDC

70

Ground

71

Operator console spare input

72

Power good low active

73

Not connected

74

Line volts

75

Not connected

76

Actual current

77

Not connected

78

Not connected