Hypertherm THC ArcGlide User Manual

Page 261

Advertising
background image

ArcGlide THC Instruction Manual 806450

261

A – ArcGlide THC Serial Communication Protocol

Maximum Speed

Command ID

Data

Examples

MD

50 – 1,000 in/min

1,270 – 25,400 mm/min

>MS60036< Sets the maximum speed to
600 in/min.

>MS152409C< Sets maximum speed to
15,240 mm/min.

>MS?DF< Inch or metric query from the CNC.

Sets the maximum linear speed that the ArcGlide THC can achieve. It is also the 100% scale for servo loop
calculations.

Default: 600 inches/min or 15,240 mm/min

Use the default when using the Hypertherm lifter with the ArcGlide.

Fast Speed

Command ID

Data

Examples

FS

50 – 1,000 in/min

1,270 – 25,400 mm/min

>FS6002F< Fast speed set to 600 in/min.

>FS1524095< Fast speed to set
15,240 mm/min.

>FS?D8< English or metric query from the CNC.

Sets the speed used for all automatic rapid moves such as the end-of-cut-retract or the initial approach to the
workpiece.

Default: 600 in/min or 15,240 mm/min

Use the default when using the Hypertherm lifter with the ArcGlide.

Slow Speed

Command ID

Data

Examples

SS

30 – 500 in/min

762 – 12,700 mm/min

>SS1503C< Slow Speed set to 150 in/min.

>SS381072< Slow speed set to 3,810 mm/min.

>SS?E5< Inch or metric query from the CNC.

Sets the homing speed and the fastest speed used for manual moves. It is also the maximum speed limit used
during arc voltage control.

Default: 150 in/min or 3,810 mm/min

Use the default when using the Hypertherm lifter with the ArcGlide.

Advertising