ArcGlide THC Instruction Manual 806450

73

2 – Installation

11 – ArcGlide with discrete connection to a Picopath interface CNC

A

B

D S

D S

CNC PLASMA

17

18

INPUT 12

OUTPUT 10

OUTPUT 11

OUTPUT 12

5

7

1

26

25

INTERLOCK

12

32

31

30

MOTION

CYCLE START

AVC DISABLE

IHS SYNC

24V COMMON

COMMON

31

24V

PULL UP

24V

PULL UP

24V

PULL UP

CUT/MARK
SENSE

RELAY

BREAKAWAY

BREAKAWAY

37

11

INPUT 11

22

21

COMMON

JUMPER

JUMPER

COMMON

29

30

TORCH

INPUT

24V

+24V

+24V

Picopath CNC end A

CNC I/O cable

Picopath interface CNC

I/O

Axes 1, 2

Axes 3, 4

ArcGlide control module

ArcGlide control module end B

Set dry contacts by sliding
the switch to D.

Picopath connector kit (228490)

End A of the Hypertherm ArcGlide CNC I/O cable is terminated during installation and will work only if the I/O setup in Phoenix software corresponds to the setup
described in this half of this table.

End B of the Hypertherm ArcGlide CNC I/O cable is terminated at the
factory as described in this half of the table.

Pin No.

Function*

Phoenix mapping name

Wire color*

Pin No.

Signal

32

Output 12

Cut Control

Red

1

Cycle start input +

31

Output 11

Hold Ignition

Blue

7

IHS sync input +

30

Output 10

Torch Height Disable

Green

5

AVC disable input +

12

Input 12**

Cut/Mark Sense

Green

17

Machine motion output A

Jumper blue and red, pins 18 and 29.

Red

18

Machine motion output B

Blue

29

Common

11

Input 11**

Torch Collision

Yellow

21

Torch breakaway output A

Jumper red and green, pins 22 and 30.

Red

22

Torch breakaway output B

Green

30

Common

External switch

Satisfy with switch or jumper.

Orange

25

Interlock input + **

Red

26

Interlock input - **

37

24 V common

Yellow

31

Common

Backshell

Chassis ground

Drain wire

Ring terminal Chassis ground

* This example uses CNC outputs 10, 11, 12, and inputs 11 and 12. Assign the I/O points in the Phoenix software.

** Set ArcGlide plasma inputs to dry (D) using the plasma input switch on the THC processor board in the control module.

* Multiple wires are the same color. Verify pin-to-pin connections before plugging cables into equipment.

** ArcGlide interlock must be closed to enable ArcGlide motion.

Advertising