Screen 7 – inputs from the operator console, Screen 8 – outputs to the operator console – Hypertherm THC ArcGlide User Manual

Page 140

Advertising
background image

140

ArcGlide THC Instruction Manual 806450

3 – Operation

Screen 7 – Inputs from the operator console

Sta Disable: Indicates whether the station is enabled at the operator console. The displayed value should be the

opposite of the value for Sta Select. On/Off

Sta Select: Indicates that the station is selected at the optional HMI or at the operator console if the operator console is

designed to select a station. The displayed value should be the opposite of the value for Sta Disable. On/Off

Torch Up: Indicates that the torch is being commanded to move up at the operator console. On/Off

Torch Dwn: Indicates that the torch is being commanded to move down at the operator console. On/Off

Spare: Reserved

Screen 8 – Outputs to the operator console

Torch Enable: Indicates that the torch is enabled at the lifter. On/Off

Error: Indicates that there is an ArcGlide error. See Screen 11 – Last errors on page 142 for more information. On/Off

Spare: Reserved

7

OPCON

INPUTS

Sta Disable

Off

Torch Dwn

Off

Sta Select

On

Spare

Off

Torch Up

Off

8

OPCON

OUTPUTS

Torch enable

On

Error

Off

Spare

Off

Advertising