Lifter – Hypertherm THC ArcGlide User Manual

Page 128

Advertising
background image

128

ArcGlide THC Instruction Manual 806450

3 – Operation

Lifter

Control

Description

1

Station status lamp

This lamp is illuminated if the lifter is enabled. The lamp flashes slowly when there is an
error. It flashes rapidly in Align mode.

When the lamp is not illuminated, the brake is locked and the lifter is disabled.

2

Station
ENABLE/DISABLE
switch

Push this switch up to enable the lifter for operation. Push the switch down to disable
the lifter for maintenance, to replace consumables, or to turn OFF the lifter.

If the plasma system allows the THC to turn it on and off and is wired appropriately,
this switch can turn ON and OFF the plasma system.

3

Lifter UP/DOWN
switch

Push this switch up or down to raise or lower the torch.

1

2

3

Advertising