Kit 228851 (new arcglide installation), Specifications – Hypertherm THC ArcGlide User Manual

Page 270

Advertising
background image

270

ArcGlide THC Instruction Manual 806450

B – ArcGlide THC Serial Communication Installation

Kit 228851 (New ArcGlide installation)

Specifications

An ArcGlide THC that uses RS-422 serial communication supports the following features:

Built-in jumpers on the adapter cables that connect to the ArcGlide control module enable serial communication and
allow the rest of the system to interact with the ArcGlide THC as if it were a Command THC

Only single-torch configurations are allowed

The HMI is optional. However, the switches on the HMI are active and allow it to be used as an operator console to
perform the following functions:

Enable or disable the lifter

Raise or lower the torch

Select Automatic or Manual mode

Perform an IHS test

The HMI only displays status and error messages from the control module. To allow the HMI to modify parameters in
a system that uses serial communication, you must remove the jumper between pins 14 and 15 in Connector A on
the Plasma I/O split cable (Z) (223253). For more information, see

ArcGlide discrete interface signal examples on

page 117. Communication between the HMI and the ArcGlide control module is carried over a Hypernet connection.
This is the only Hypernet connection in the RS-422 serial configuration.

Plasma I/O is carried on a discrete cable. The RS-422 signals that are sent from the plasma board on the control
module are diverted to the CNC.

Part number

Description

Quantity

223262

Plasma I/O to THC control module cable with serial split
(Y adapter)

1

074067

Quick-disconnect ground terminal

1