Plasma cutting tips, Cut quality issues – Hypertherm THC ArcGlide User Manual

Page 161

Advertising
background image

ArcGlide THC Instruction Manual 806450

161

3 – Operation

Plasma cutting tips

The following reference guide offers several solutions to help improve cut quality.

Consider the following factors when evaluating plasma cut quality:

Type of machine (example: XY table, punch press)

Plasma cutting system (example: plasma system, torch, consumables)

Motion control device (example: CNC, torch height control)

Process variables (example: cutting speed, gas pressures, flow rates)

External variables (example: material variability, gas purity, operator experience)

All of these factors can affect the appearance of a cut.

Cut quality issues

Angularity

Positive cut angle: More material is removed from the top of the cut surface than from the bottom.

Negative cut angle: More material is removed from the bottom of the cut surface than from the top.

Advertising