Freescale Semiconductor MCF5480 User Manual

Page 141

Advertising
background image

Exception Processing Overview

MCF548x Reference Manual, Rev. 3

Freescale Semiconductor

3-37

If the exception is caused by an FPU instruction, the PC contains the address of either the next

floating-point instruction (nextFP) if the exception is pre-instruction, or the faulting instruction

(fault) if the exception is post-instruction.

3. The processor acquires the address of the first instruction of the exception handler. The instruction

address is obtained by fetching a value from the exception table at the address in the vector base
register. The index into the table is calculated as 4 x vector_number. When the index value is
generated, the vector table contents determine the address of the first instruction of the desired
handler. After the fetch of the first opcode of the handler is initiated, exception processing
terminates and normal instruction processing continues in the handler.

The vector base register described in the ColdFire Programmers Reference Manual, holds the base address

of the exception vector table in memory. The displacement of an exception vector is added to the value in

this register to access the vector table. VBR[19–0] are not implemented and are assumed to be zero, forcing

the vector table to be aligned on a 0-modulo-1-Mbyte boundary.
ColdFire processors support a 1,024-byte vector table aligned on any 0-modulo-1 Mbyte address

boundary; see

Table 3-21

. The table contains 256 exception vectors, the first 64 of which are defined by

Freescale. The rest are user-defined interrupt vectors.

Table 3-21. Exception Vector Assignments

Vector Numbers Vector Offset (Hex)

Stacked Program Counter

1

Assignment

0

000

Initial supervisor stack pointer

1

004

Initial program counter

2

008

Fault Access

error

3

00C

Fault

Address error

4

010

Fault

Illegal instruction

5

014

Fault

Divide by zero

6–7

018–01C

Reserved

8

020

Fault

Privilege violation

9

024

Next

Trace

10

028

Fault

Unimplemented line-a opcode

11

02C

Fault

Unimplemented line-f opcode

12

030

Next

Non-PC breakpoint debug interrupt

13

034

Next

PC breakpoint debug interrupt

14

038

Fault

Format error

15

03C

Next

Uninitialized interrupt

16–23

040–05C

Reserved

24

060

Next

Spurious interrupt

25–31

064–07C

Next

Level 1–7 autovectored interrupts

32–47

080–0BC

Next

Trap #0–15 instructions

Advertising