Figure 21-12 – Freescale Semiconductor MCF5480 User Manual

Page 590

Advertising
background image

MCF548x Reference Manual, Rev. 3

21-20

Freescale Semiconductor

31

30

29

28

27

26

25

24

23

22

21

20

19 18 17 16

15

14 13 12 11 10

9

8

7

6

5

4

3

2

1

0

0x0

CODE

SRR IDE RTR

LENGTH

TIME STAMP

0x4

Standard ID [28:18]

Extended ID [17:0]

0x8

Data Byte 0

Data Byte 1

Data Byte 2

Data Byte 3

0xC

Data Byte 4

Data Byte 5

Data Byte 6

Data Byte 7

Figure 21-12. Message Buffer Structure for Both Extended and Standard Frames

Table 21-13. Message Buffer Field Descriptions

Bits

Name

Description

31–28

Reserved, should be cleared. Should not be accessed by the CPU.

27–24

CODE

Message buffer code. This 4-bit field can be accessed (read or write) by the CPU and by the
FlexCAN module itself, as part of the message buffer matching and arbitration process. The
encoding is shown in

Table 21-14

and

Table 21-15

. See

Section 21.4, “Functional Overview

” for

additional information.

23

Reserved, should be cleared. Should not be accessed by the CPU.

22

SRR

Substitute remote request. Fixed recessive bit, used only in extended format. It must be set to 1 by
the user for transmission (Tx Buffers) and will be stored with the value received on the CAN bus
for Rx receiving buffers. It can be received as either recessive or dominant. If FlexCAN receives
this bit as dominant, then it is interpreted as arbitration loss.
0 Dominant is not a valid value for transmission in Extended Format frames
1 Recessive value is compulsory for transmission in Extended Format frames

21

IDE

ID extended bit. This bit identifies whether the frame format is standard or extended.
0 Frame format is standard
1 Frame format is extended

20

RTR

Remote transmission request. This bit is used for requesting transmissions of a data frame. If
FlexCAN transmits this bit as 1 (recessive) and receives it as 0 (dominant), it is interpreted as
arbitration loss. If this bit is transmitted as 0 (dominant), then if it is received as 1 (recessive), the
FlexCAN module treats it as bit error. If the value received matches the value transmitted, it is
considered as a successful bit transmission.
0 Indicates the current MB has a data frame to be transmitted
1 Indicates the current MB has a remote frame to be transmitted

19–16

LENGTH

Length of data in bytes. This 4-bit field is the length (in bytes) of the Rx or Tx data; data is located
in offset 0x8 through 0xF of the MB space (see

Figure 21-12

). In reception, this field is written by

the FlexCAN module, copied from the DLC (data length code) field of the received frame. DLC is
defined by the CAN Specification and refers to the data length of the actual frame before it is copied
into the message buffer. In transmission, this field is written by the CPU and is used as the DLC
field value of the frame to be transmitted.
When RTR = 1, the frame to be transmitted is a remote frame and will be transmitted without the
DATA field, regardless of the LENGTH field.

15–0

TIME

STAMP

Free-running counter time stamp. This field stores the 16-bit value of the free-running timer. The
timer value is captured at the beginning of the identifier field of the frame on the CAN bus.

Advertising
This manual is related to the following products: