Cross cutter, Features of the "cross cutter" prepared solution – Lenze EVS93xx CrossCutter User Manual
Page 110
Advertising
![background image](/manuals/566149/110/background.png)
Cross Cutter
Features of the "Cross Cutter" prepared solution
Prepared Solution Servo PLC / ECSxA 1.1 EN
2-96
Possible settings:
Code
Default
Selection
Comment
Inversion of DFIN signal
TRUE Invert
DFIN
signal.
C3635/
000
0 0
...
{1}
...1
FALSE No
inversion.
Inversion of motor mounting direction
TRUE
Motor left mounting (inverted)
C3636/
000
0 0
...
{1}
...1
FALSE
Motor right mounting (not inverted)
C3681/
000
0
0 ...
{1 rpm}
...15000
Selection of the simulation value for DFIN simulation.
Application control word bit 10: Activates master value simulation.
TRUE
Master value is simulated via code C3681/000
(g_nTestsignalDFIN_v).
C4135/
000
Bit 10
0
0 {1} 1
FALSE
Master value is used by DFIN input.
Advertising