Cross Cutter

Appendix



Prepared Solution Servo PLC / ECSxA 1.1 EN

6-74

The signal sources for the data words (designated Word 0, Word 1, Word 2 and Word 3) are
dependent on the operating mode in C4000/000:

Signal source

Word 0

Word 1

Word 2

Word 3

C4000/000 = 0

C0135/000

C4137/000

C4135/000

C4000/000 = 1

CAN1_wDctrlCtrl CAN1_nInW1_a CAN1_nInW2_a CAN1_nInW3_a

C4000/000 = 2

CAN2_nInW1_a CAN2_nInW2_a CAN2_nInW3_a CAN2_nInW4_a

C4000/000 = 3

CAN3_nInW1_a CAN3_nInW2_a CAN3_nInW3_a CAN3_nInW4_a

C4000/000 = 4

AIF1_wDctrlCtrl AIF1_nInW1_a AIF1_nInW2_a AIF1_nInW3_a

C4000/000 = 5

AIF2_nInW1_a AIF2_nInW2_a AIF2_nInW3_a AIF2_nInW4_a

C4000/000 = 6

AIF3_nInW1_a AIF3_nInW2_a AIF3_nInW3_a AIF3_nInW4_a

The illustration of the 32-bit application control word (Word 3 and Word 4) on the previous page
shows the factory-set default configuration. Users can also adapt the configuration of the
application control word in accordance with their individual needs by setting the values of codes
C4010/001 to C4010/032 accordingly.

An example of how the GDC parameterisation software can be used to reconfigure the
application control word bit by bit appears below:

You will find the code in the complete code list or in the menu (Short Setup Control/Status Interface
Control Interface):

Select code C4010/00x which is assigned to the function to be configured.
Example: The control signal for manual jog in a positive direction is defined in code C4010/004:


Start

Step 1