Cross cutter, Appendix – Lenze EVS93xx CrossCutter User Manual

Page 181

Advertising
background image

Cross Cutter

Appendix



Prepared Solution Servo PLC / ECSxA 1.1 EN

6-13

Outputs

Global variables

(Variable type: VAR_GLOBAL)

Name Data

type

Value/Meaning

Status signal: All calculation sequences for new cross-cutter motion profiles have
been completed successfully.
TRUE

All calculation sequences for new cross-
cutter motion profiles have been
completed successfully.
Starting a new calculation sequence will

reset this status output to FALSE.

g_bAllCalcDone BOOL

FALSE

All calculation sequences for new cross-
cutter motion profiles are still in
progress.

Status signal: The motion profile for the cutting length needs to be recalculated due
to changes to input values for the calculation.
TRUE

Need to recalculate.

g_bAnotherRoundCalcCuttingProfile BOOL

FALSE

Do not need to recalculate.

Status signal: The motion profile for the reject length needs to be recalculated due
to changes to input values for the calculation.
TRUE

Need to recalculate.

g_bAnotherRoundCalcRejectProfile BOOL

FALSE

Do not need to recalculate.

Status signal: The motion profile for the test length needs to be recalculated due to
changes to input values for the calculation.
TRUE

Need to recalculate.

g_bAnotherRoundCalcTestProfile BOOL

FALSE

Do not need to recalculate.

Status signal: The motion profile for the start/stop length needs to be recalculated
due to changes to input values for the calculation.
TRUE

Need to recalculate.

g_bAnotherRoundCalcStartStopProfile BOOL

FALSE

Do not need to recalculate.

g_nMaxMasterVelForActCuttingProfile_v INT Entry

indicating

the maximum possible line speed for the set cutting length in

[incr./ms].

g_nMaxMasterVelForActRejectProfile_v INT

Entry indicating the maximum possible line speed for the set reject length in

[incr./ms].

g_nMaxMasterVelForActTestProfile_v

INT

Entry indicating the maximum possible line speed for the set test length in [incr./ms].

g_nMaxMasterVelForActStartStopProfile_v

INT

Entry indicating the maximum possible line speed for the set start/stop length in
[incr./ms].

g_nMaxMasterVelForActAsyCuttingProfile_v INT

Entry

indicating

the maximum possible line speed for the set asynchronus cutting

length in [incr./ms].

g_dnDistanceToXMax

DINT

Distance between finishing point of motion profile and 6 o'clock position on knife in
0.0001[m_units].

If you use this variable, to avoid inconsistencies, do not write variable
g_dnDistanceToXMax_p!

g_dnDistanceToXMax_p

DINT

Distance between finishing point of motion profile and 6 o'clock position on knife in

0.0001[incr.].

If you use this variable, to avoid inconsistencies, do not write variable
g_dnDistanceToXMax!

g_nNumberOfKnifes INT

Number of knives mounted on the knife drum.