Appendix



Prepared Solution Servo PLC / ECSxA 1.1 EN

6-32

Inputs

Global variables

(Variable type: VAR_GLOBAL)

quick stop (QSP).

Outputs

Global variables

(Variable type: VAR_GLOBAL)

Name Data

type

Value/Meaning
"Traversing to X position on motion profile active" status signal

g_bLockToCamBusy BOOL

TRUE

Moves the drive to the corresponding
position on the motion profile.

"X position on motion profile reached" status signal

g_bLockToCamDone BOOL

TRUE

The drive has arrived at the
corresponding position on the motion
profile.

Display indicating the main states of the template
100 "Init"

state

51 "LockToCamBusy"

state

50 "CamOperation"

state

40 "PositioningOperation"

state

30 "HomingOperation"

state

20 "ManualOperation"

state

10 "StandBy"

state


Switching over to other states is
performed from this initial state.

g_byOperationState BYTE

1 "Trouble"

state

6.1.16 VarTorquePrecontrol

Inputs

Global variables

(Variable type: VAR_GLOBAL)

Name Data

type

Value/Meaning
Enable acceleration precontrol.

External torque precontrol remains enabled even when acceleration

precontrol is disabled.

g_bTorquePrecontrolEnable

BOOL

TRUE

Acceleration precontrol enabled.

g_nFactorInertia_a

INT

Factor for adapting the precontrol value to the moment of inertia of the
drive

Value range: −32767 ... 32767

16384 = 100%

The variable is a retain variable.

g_nTorquePreAdd_a

INT

External torque precontrol

Remains activated even when acceleration precontrol is deactivated.

Outputs

Global variables

(Variable type: VAR_GLOBAL)

Name Data

type

Value/Meaning

g_nSetTorquePrecontrol_a

INT

Resulting precontrol for torque controller

16384 = 100%