6.3 Error

messages

Where error messaged are concerned, the prepared solutions draw a distinction between what
are known as system error messages (see Chapter 6.3.1) and process-based error messages
(advanced error messages, see Chapter 6.3.2 and Chapter 6.3.3).

6.3.1

System error messages

System error messages are generated in the target system's operating system in response to all
impermissible drive-based states (e.g. overcurrent, undervoltage, errors in the feedback system,
etc.).

The following system error messages can occur on the ServoPLC:

Error

number

Error code

Cause

Remedy

Actual short circuit between motor
phases

Disconnect the motor and check for short circuits
between all winding connections.
Disconnect the supply cable and check for short
circuits between phases.
Run the inverter off-load: It ought to be possible to
reset the error at this point. If it is not, an internal
short circuit has occurred => Replace the controller
or submit it for repair.

11

OC1

High capacitive charging current on
the motor cable

Use a shorter, low-capacitance motor cable.
Install an output choke at the controller's output
phases.

Actual earth fault on one of the motor
phases

Disconnect the motor and check the winding
connections for earth faults.
Disconnect the supply cable and check for short
circuits between phases and earth.
Run the inverter off-load: It ought to be possible to
reset the error at this point. If it is not, an internal
earth fault has occurred => Replace the controller or
submit it for repair.

12

OC2

High capacitive charging current on
the motor cable

Use a shorter, low-capacitance motor cable.
Install an output choke at the controller's output
phases.

Frequent/excessively long
acceleration processes with
overcurrent (I

motor

> I

rated, inverter

)

15

OC5

Continuous overload with I

motor

> 1.05

x I

rated, inverter

Check the drive dimensioning; you may need to
increase the drive's power rating.

16

OC6

I2 x t overload (C0120)

Check the settings in C0120/000.
Check the drive dimensioning; you may need to
increase the drive's power rating.

17

OC7

I x t warning (C0123)

Check the settings in C0123/000.
Check the drive dimensioning; you may need to
increase the drive's power rating.

18

OC8

I2 x t warning (C0127)

Check the settings in C0127/000.
Check the drive dimensioning; you may need to
increase the drive's power rating.