Cross cutter – Lenze EVS93xx CrossCutter User Manual
Page 161
Cross Cutter
Installing and starting up the "CrossCutter" prepared solution
Prepared Solution Servo PLC / ECSxA 1.1 EN
3-147
You now need to switch to the application control word (Short Setup Control/Status Interface Control
Interface):
Select the operating mode you wish to use in code C4137/000:
1 Cutting
mode
2 Reject mode
3 Test
mode
4 Asynchr.
mode
TIP!
•
You cannot switch from operating mode 1 to operating mode 4 during operation.
In order to switch modes, the system must be in standby
(C3505/000=Standby(10)).
•
You cannot switch from operating mode 4 to operating mode 1 during operation.
In order to switch modes, the system must be in standby
(C3505/000=Standby(10)).
Caution!
Mark-controlled operation is only supported by the system in operating modes 1 and 4. In
all other operating modes, mark-controlled operation is suppressed automatically by the
system!
Step 6