Cross Cutter

Features of the "Cross Cutter" prepared solution



Prepared Solution Servo PLC / ECSxA 1.1 EN

2-80

Variable

names

Inputs

Global variables

(Variable type: VAR_GLOBAL)

Name Data

type

Value/Meaning

g_wRejectGateSwitchingDwelltime

WORD

Selection of the switching dwell time (switching delay time) of the reject gate in ms.

This value is displayed in code C3680/000; this variable can be written to this code.

g_dnDistanceRejectGate

DINT

Selection of the distance from the reject gate to the cutting position in
0.0001[m_units].

This value is displayed in code C3679/000; this variable can be written to this code.
The value is converted into increments internally. If you use this variable, to avoid
inconsistencies, do not write variable g_dnDistanceRejectGate_p!

g_dnDistanceRejectGate_p

DINT

Selection of the distance from the reject gate to the cutting position in [incr.].

If you use this variable, to avoid inconsistencies, do not write variable
g_dnDistanceRejectGate!

Outputs

Global variables

(Variable type: VAR_GLOBAL)

Name Data

type

Value/Meaning

This output is used to control the reject gate.

This value is displayed in code C4150/000 bit 25.
The variable is permanently linked to digital output 3 using 9300 Servo PLC or
digital output 1 using ECS.

TRUE

Open the reject gate.

g_bOpenRejectGate BOOL

FALSE

Do not open the reject gate.

Possible settings:

Code

Default

Selection

Comment

C3679/

000

0.0000 0.0000...

{0.0001

m_units}

... 214000.0000

Distance from reject gate to cutting position

C3680/

000

0

0 ...

{1 ms}

... 65535

Switching dwell time (switching delay time) of reject gate

Application status word bit 25: Control of reject gate

TRUE

Open the reject gate.

C4150/

000

Bit 25

-

- - -

FALSE

Do not open the reject gate.