Cross cutter, Features of the "cross cutter" prepared solution – Lenze EVS93xx CrossCutter User Manual

Page 55

Advertising
background image

Cross Cutter

Features of the "Cross Cutter" prepared solution



Prepared Solution Servo PLC / ECSxA 1.1 EN

2-41

Possible settings:

Code

Default

Selection

Comment

Application status word bit 20: The cross cutter is operating as an
asynchronous cross cutter.
TRUE

The cross cutter is operating as an asynchronous
cross cutter.

C4150/

000

Bit 20

-

- - -

FALSE

The cross cutter is not operating as an asynchronous
cross cutter.

Application status word bit 21: The cross cutter is operating as a
synchronous cross cutter.

TRUE

The cross cutter is operating as a synchronous cross
cutter.

C4150/

000

Bit 21

-

- - -

FALSE

The cross cutter is not operating as a synchronous
cross cutter.

Application status word bit 22: The cross cutter is operating in
"Continuous cutting" mode.

TRUE

The cross cutter is operating in "Continuous cutting"
mode.

C4150/

000

Bit 22

-

- - -

FALSE

The cross cutter is not operating in "Continuous
cutting" mode.

Application status word bit 23: The cross cutter is operating in
"Reject operation" mode.

TRUE

The cross cutter is operating in "Reject operation"
mode.

C4150/

000

Bit 23

-

- - -

FALSE

The cross cutter is not operating in "Reject operation"
mode.

Application status word bit 24: The cross cutter is operating in
"Test operation" mode.
TRUE

The cross cutter is operating in "Test operation"
mode.

C4150/

000

Bit 24

-

- - -

FALSE

The cross cutter is not operating in "Test operation"
mode.

Application status word 31: All calculation sequences for new
cross-cutter motion profiles have been completed successfully.
Starting a new calculation sequence will reset this status output to

FALSE.
TRUE

All calculation sequences for new cross-cutter motion
profiles have been completed successfully.

C4150/

000

Bit 31

-

- - -

FALSE

All calculation sequences for new cross-cutter motion
profiles are still in progress.

The warning signals listed in the following table may appear when calculating cross-cutter
motion profiles. Each warning signal will remain pending until its cause has been dealt with.

Each warning signal is generated in the specified network of the UserErrors block (POU).

Warning signals

Number

Text

Global variable

Network in
UserErrors
POU

501 WrongProfileForCalc

g_bWrongSetCamProfileNoForCalc

2

503 ErrorCalcCuttingProfile

g_bErrorCrossCutterCuttingProfileCalcBlock 4

504 ErrorCalcRejectProfile

g_bErrorCrossCutterRejectProfileCalcBlock 5

505 ErrorCalcTestProfile

g_bErrorCrossCutterTestProfileCalcBlock 6

506 ErrorCalcStartStopProfile

g_bErrorCrossCutterStartStopProfileCalcBlock 7

Advertising