Cross Cutter
Features of the "Cross Cutter" prepared solution
Prepared Solution Servo PLC / ECSxA 1.1 EN
2-70
Outputs
(Variable type: VAR_GLOBAL)
Name Data
type
Value/Meaning
This output signal indicates that the maximum number of cycles completed without
a mark signal appearing in the mark window has been exceeded.
This value is displayed in code C4150/000 bit 26.
TRUE
The maximum number of cycles without a mark signal appearing
in the mark window has been reached.
g_bMaxNumberOfTPOutOfWindow
Increased
BOOL
FALSE
The maximum number of cycles without a mark signal appearing
in the mark window has not been reached.
g_wNumberOfTpOutOfWindow
WORD
Number of cycles completed without a mark signal appearing in the mark window.