Code initialisation values

The following codes are initialised on a project-specific basis and differ from the default setting
initialisation values.

Code Initialisation

Comment

C0114/001

1,0000

Inversion of digital input I1 (0V = QSP) using 9300 Servo PLC

C0114/004

1,0000

Inversion of digital input I4 (0V = QSP) using ECS

C0352/000

1,0000

Device declared as CAN boot-up master.

C0427/000

0,0000

DFIN function of master signal is "2 phases".

C0428/000

1,0000

DFIN touch-probe source is digital input I5 (terminal X5/I5).

C0469/000

0,0000

Deactivation of stop pushbutton (keypad)

C0540/000

4,0000 DFOUT

X9=X10

C2104/000

1,0000 PLC

auto-start

C3649/001

0.1000

Time for abort ramp during print-mark synchronisation

C4010/002

1,0000

Control bit 1 Home position set read from input bit 1

C4010/003

2,0000

Control bit 2 Home position reset read from input bit 2

C4010/004

3,0000

Control bit 3 Manual jog in positiv read from input bit 3

C4010/005

4,0000

Control bit 4 Manual jog in negativ read from input bit 4

C4010/006

5,0000

Control bit 5 Positioning start read from input bit 5

C4010/007

6,0000

Control bit 6 User trip set read from input bit 6

C4010/008

7,0000

Control bit 7 Trip reset read from input bit 7

C4010/009

8,0000

Control bit 8 Controller inhibit read from input bit 8

C4010/010

9,0000

Control bit 9 Quickstop read from input bit 9

C4010/011

10,0000

Control bit 10 Switch to internal line speed (C3681) read from input bit 10

C4010/012

11,0000

Control bit 11 Reset cutting length counter read from input bit 11

C4010/013

12,0000

Control bit 12 Reset reject length counter read from input bit 12

C4010/014

13,0000

Control bit 13 Reset test length counter read from input bit 13

C4010/015

14,0000

Control bit 14 Automatic mode (Cross cutter operation) read from input bit 14

C4010/016

15,0000

Control bit 15 Accept cutting length read from input bit 15

C4010/017

16,0000

Control bit 16 Accept reject length read from input bit 16

C4010/018

17,0000

Control bit 17 Accept test length read from input bit 17

C4010/019

18,0000

Control bit 18 Activate x-trimming read from input bit 18

C4010/020

19,0000

Control bit 19 Positiv x-trimming read from input bit 19

C4010/021

20,0000

Control bit 20 Negativ x-trimming read from input bit 20

C4010/022

21,0000

Control bit 21 Enable print-mark controller read from input bit 21

C4010/023

22,0000

Control bit 22 Ramp based adjustment read from input bit 22

C4010/024

23,0000

Control bit 23 Reset missingmark counter read from input bit 23

C4010/025

24,0000

Control bit 24 Abort cross cutter operation read from input bit 24

C4010/026

25,0000

Control bit 25 Activate x-trimming positioning read from input bit 25

C4010/027

26,0000

Control bit 26 not assigned read from input bit 26

C4010/028

27,0000

Control bit 27 not assigned read from input bit 27

C4010/029

28,0000

Control bit 28 not assigned read from input bit 28

C4010/030

29,0000

Control bit 29 not assigned read from input bit 29

C4010/031

30,0000

Control bit 30 not assigned read from input bit 30

C4010/032

31,0000

Control bit 31 not assigned read from input bit 31

C4012/002

1,0000

Status bit 1 output to output bit 1, Follow error warning

C4012/003

2,0000

Status bit 2 output to output bit 2, Follow error trip

C4012/004

3,0000

Status bit 3 output to output bit 3, Positioning active

C4012/005

4,0000

Status bit 4 output to output bit 4, Positioning done

C4012/006

5,0000

Status bit 5 output to output bit 5, Lock to cam busy

C4012/007

6,0000

Status bit 6 output to output bit 6, Cross Cutter Operation

C4012/008

7,0000

Status bit 7 output to output bit 7, Print mark correction active

C4012/009

8,0000

Status bit 8 output to output bit 8, Recalculation of cutting profile

C4012/010

9,0000

Status bit 9 output to output bit 9, Recalculation of reject profile

C4012/011

10,0000

Status bit 10 output to output bit 10, Recalculation of test profile

C4012/012

11,0000

Status bit 11 output to output bit 11, Recalculation of start/stop profile

C4012/013

12,0000

Status bit 12 output to output bit 12, Calculation of cutting profile OK

C4012/014

13,0000

Status bit 13 output to output bit 13, Calculation of reject profile OK

C4012/015

14,0000

Status bit 14 output to output bit 14, Calculation of test profile OK

C4012/016

15,0000

Status bit 15 output to output bit 15, Calculation of start/stop profile OK

C4012/017

16,0000

Status bit 16 output to output bit 16, Homing busy

C4012/018

17,0000

Status bit 17 output to output bit 17, Home position available

C4012/019

18,0000

Status bit 18 output to output bit 18, Homing error

C4012/020

19,0000

Status bit 19 output to output bit 19, NC

C4012/021

20,0000

Status bit 20 output to output bit 20, Asynchronus cutting operation