Cross cutter – Lenze EVS93xx CrossCutter User Manual
Page 143
![background image](/manuals/566149/143/background.png)
Cross Cutter
Installing and starting up the "CrossCutter" prepared solution
Prepared Solution Servo PLC / ECSxA 1.1 EN
3-129
You now need to make the parameter settings for homing (Short Setup Homing):
TIP!
See Chapter 2.5.6 for more information about homing.
Make the following code settings:
C3010/000 Homing
mode
C3624/001 Homing: Deceleration time (abort)
C3624/002 Homing: Acceleration time
C3624/003 Homing: Deceleration time
C3625/001 Homing: Positive traversing speed
C3625/002 Homing: Negative traversing speed
C3626/000 Position of homing switch
C3627/000 Target position of axis following homing
If you are using a homing mode which requires a TP sensor signal you will also have to set the TP source:
C0911/000 MCTRL Touch-probe source
C0912/000 MCTRL Touch-probe edge
Step 7