Cross cutter, Appendix – Lenze EVS93xx CrossCutter User Manual

Page 209

Advertising
background image

Cross Cutter

Appendix



Prepared Solution Servo PLC / ECSxA 1.1 EN

6-41

Possible settings:

Code

Default

Selection

Comment

Positioning mode
0

Move to target position via shortest route.

1

Move to target position only in positive
direction (CW).

2

Move to target position only in negative
direction (CCW).

C3629/

000

0

0 {1} 4

4

Positioning relative to entry in C3628/000
(g_dnToolPositionSet).

Positioning mode Lock to cam
0

Move to cam position via shortest route.

1

Move to cam position only in positive
direction (CW).

C3630/

000

0

0 {1} 2

2

Move to cam position only in negative

direction (CCW).

Inversion of DFIN signal
TRUE

Invert DFIN signal.

C3635/

000

0

0 {1} 1

FALSE

Do not invert DFIN signal.

Motor mounting direction
TRUE

Motor mounting direction inverted.

C3636/

000

0

0 {1} 1

FALSE

Motor mounting direction not inverted.

C3637/

000

1

-32767 {1}

...

32767 Gearbox (numerator) position feedback

It is not allowed to set the value Zero!

C3638/

000

1

1... {1}

...

32767

Gearbox (denominator) position feedback

C3639/

000

1

-200... {1

%} ...

200

external torque precontrol

Function of external torque precontrol
0

TorqueOut = TorqueIn1

1

TorqueOut = TorqueIn1 + TorqueIn2

2

TorqueOut = TorqueIn1 − TorqueIn2

3

TorqueOut =

16384

2

1 TorqueIn

TorqueIn

4

TorqueOut =

164

2

1 ⋅

TorqueIn

TorqueIn

C3640/

000

1

0 {1} 5

5

TorqueOut =

16384

2

16384

1

TorqueIn

TorqueIn

C3643

3.0000

0.0001... {0.0001

[s_units]}

... 214748.0000 Selection of following error switch-off threshold

C3644

0.5000

0.0001... {0.0001

[s_units]}

... 214748.0000 Selection of following error hysteresis

C3645

1.5000

0.0001... {0.0001

[s_units]}

... 214748.0000 Selection of following error warning limit

C3646

0.5000

0.0001... {0.0001

[s_units]}

... 214748.0000 Selection of following error warning limit hysteresis

C3649/

001

0.100

0.000... {0.01[s]} ...129.99 Abort ramp for ramp generator: Assumes a speed of 4000 rpm.

Used if the knife cuts into the material whilst mark correction is in
progress.

C3649/

002

5.000

0.000... {0.01[s]} ...129.99 Acceleration ramp for ramp generator: Assumes a speed of 4000

rpm.

C3649/

003

5.000

0.000... {0.01[s]} ...129.99 Deceleration ramp for ramp generator: Assumes a speed of 4000

rpm.

C3650/

001

200

0 {1

rpm}

15000 Maximum positive correction speed for mark synchronisation with

a ramp generator and correction speed for mark synchronisation
without a ramp generator.

C3650/

002

200

{1

rpm}

15000 Maximum negative correction speed for mark synchronisation

with a ramp generator.

C3653/

000

628.3185 0.0000...

{0.0001

m_units}

... 214748.0000

Cutting circle circumference of knife drum