Cross Cutter

Appendix



Prepared Solution Servo PLC / ECSxA 1.1 EN

6-77

The individual status words are output to system variables (designated Word 0, Word 1, Word 2
a
nd Word 4) dependent on the operating mode in C4000/000:

Signal source

Word 0

Word 1

Word 2

Word 3

C4000/000 = 0

C0135/000

C4152/000

C4150/000

C4000/000 = 1

CAN1_wDctrlStat CAN1_nOutW1_a CAN1_nOutW2_a CAN1_nOutW3_a

C4000/000 = 2

CAN2_nOutW1_a CAN2_nOutW2_a CAN2_nOutW3_a CAN2_nOutW4_a

C4000/000 = 3

CAN3_nOutW1_a CAN3_nOutW2_a CAN3_nOutW3_a CAN3_nOutW4_a

C4000/000 = 4

AIF1_wDctrlStat AIF1_nOutW1_a AIF1_nOutW2_a AIF1_nOutW3_a

C4000/000 = 5

AIF2_nOutW1_a AIF2_nOutW2_a AIF2_nOutW3_a AIF2_nOutW4_a

C4000/000 = 6

AIF3_nOutW1_a AIF3_nOutW2_a AIF3_nOutW3_a AIF3_nOutW4_a

The illustration on the previous page shows the factory-set default configuration of the 32-bit
application status word. Users can also adapt the configuration of the application status word in
accordance with their individual needs by setting the values of codes C4012/001 to C4012/032
accordingly.

An example of how the GDC parameterisation software can be used to reconfigure the
application status word bit by bit appears below:

You will find the code in the complete code list or in the menu Short Setup Control/Status Interface
Status Interface:

Select the application status word bit you wish to reconfigure.
Example: To assign bit 6 of the application status word, select code C4012/007:


Start

Step 1