Cross cutter, Features of the "cross cutter" prepared solution – Lenze EVS93xx CrossCutter User Manual

Page 68

Advertising
background image

Cross Cutter

Features of the "Cross Cutter" prepared solution



Prepared Solution Servo PLC / ECSxA 1.1 EN

2-54

Possible settings:

Code

Default

Selection

Comment

Homing mode
0 >_Rn_MP
1 <_Rn_MP
4 >_Rp_<_Rn_MP
5 <_Rp_>_Rn_MP
6 >_Rn_>_TP
7 <_Rn_<_TP
8 >_TP
9 <_TP

C3010

0

0 {1} 9

Symbols for code C3010:
> Movement in positive direction
< Movement in negative direction
Rp Positive edge of homing switch
Rn Negative edge of homing switch
TP Touch-probe edge of input I4 using Servo PLC or I2 using
ECS
MP Zero pulse edge of motor
(one per motor revolution)
The execution of the last action in each case will set the home
position (e.g. the zero pulse in the case of "MP") even if the drive

continues to move subsequently.

C3624

/001

5.00 0.01…

{0.01[s]}

...129.99 Deceleration ramp for immediate stop (function abort) for homing

Assuming 4000 rpm

C3624

/002

5.00 0.01…

{0.01[s]}

...129.99 Acceleration ramp for homing

Assuming 4000 rpm

C3624

/003

5.00 0.01…

{0.01[s]}

...129.99 Deceleration ramp for homing

Assuming 4000 rpm

C3625

/001

200

0 ...

{1 rpm}

...15000 Speed for homing in positive direction (CW)

C3625

/002

200

0 ...

{1 rpm}

...15000 Speed for homing in negative direction (CCW)

C3626
/000

0 0

{0.0001
[s_units]}

214000.0000 Entry indicating the position of the homing switch

C3627
/000

0 0

{0.0001
[s_units]}

214000.0000 Target position of tool following homing

Application control word bit 0: Start/stop homing, only in
conjunction with controller enable.

FALSE => TRUE Start homing.

C4135/

000

Bit 0

0

0 {1} 1

FALSE Stop/abort

homing.

Application control word bit 1: Set home position.

FALSE => TRUE The setpoint defined in C3626 (position of

homing switch) is applied and
g_bHomingDone is set to TRUE.

C4135/

000

Bit 1

0

0 {1} 1

FALSE

Home position not set.

Application control word bit 2: Reset home position.
TRUE

The home position is reset. The
g_bHomingDone output is reset to FALSE.
The "Home position detected" status is reset.

C4135/

000

Bit 2

0

0 {1} 1

FALSE

Home position not reset.