4 varcrosscutterpiececounter, Varcrosscutterpiececounter -15, Cross cutter – Lenze EVS93xx CrossCutter User Manual

Page 183: Appendix

Advertising
background image

Cross Cutter

Appendix



Prepared Solution Servo PLC / ECSxA 1.1 EN

6-15

6.1.4 VarCrossCutterPieceCounter

Inputs

Global variables

(Variable type: VAR_GLOBAL)

Name Data

type

Value/Meaning
Reset cutting counter for cutting operation.

TRUE Reset

counter.

g_bResetCuttingProfileCounter

BOOL

FALSE

Counter will not be reset.

Reset cutting counter for reject operation.

TRUE

Reset counter.

g_bResetRejectProfileCounter

BOOL

FALSE

Counter will not be reset.

Reset cutting counter for test operation.

TRUE

Reset counter.

g_bResetTestProfileCounter

BOOL

FALSE

Counter will not be reset.

g_wSetValuePiecesOfCuttingProfile

WORD

Setpoint cutting quantity for cutting operation

g_wSetValuePiecesOfTestProfile

WORD

Setpoint cutting quantity for reject operation

g_wSetValuePiecesOfRejectProfile

WORD

Setpoint cutting quantity for test operation

Outputs

Global variables

(Variable type: VAR_GLOBAL)

Name Data

type

Value/Meaning

Status signal: The set cutting quantity has been reached for cutting operation.

TRUE

Set cutting quantity reached.

g_bSetValueOfCuttingPiesesCutting
ProfileReached

BOOL

FALSE

Set cutting quantity not reached.

Status signal: The set cutting quantity has been reached for reject operation.

TRUE

Set cutting quantity reached.

g_bSetValueOfCuttingPiesesReject
ProfileReached

BOOL

FALSE

Set cutting quantity not reached.

Status signal: The set cutting quantity has been reached for test operation.

TRUE

Set cutting quantity reached.

g_bSetValueOfCuttingPiesesTest
ProfileReached

BOOL

FALSE

Set cutting quantity not reached.

g_wCounterValueCuttingProfile WORD Cutting counter for cutting operation

The counter is limited to a maximum value of 65535; on reaching this value it will
overflow to 0.

g_wCounterValueRejectProfile

WORD

Cutting counter for reject operation
The counter is limited to a maximum value of 65535; on reaching this value it will
overflow to 0.

g_wCounterValueTestProfile

WORD

Cutting counter for test operation
The counter is limited to a maximum value of 65535; on reaching this value it will
overflow to 0.

Advertising